Bobby, yes that would rule out the power source, or the outlet as being the problem. Thats either gears not engaged, or stuck or its a dead motor (timer motor). I checked the pump and is is very hot. Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. Im not sure what happened. Tighten the fitting hand tight, plus 1/2 turn or so, until really snug, but not super-tight. Do you have any suggestion for similar pump? No lights are coming on as if no power. Of course, be sure the pool water level is good, and the skimmer weir door is not stuck, or blocking water flow into a skimmer. Articles and resources for swimming pool owners and DIYers. Any thoughts? The loose wire you found in the pump, that was a good catch, there should be no hanging wires in the rear of the motor, all wires from the terminal board, to the switches and capacitor should be tightly connected, and the metals ends should never touch any other metal parts, except the terminal they connect to Retrace your steps to recheck power to the motor. So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. "datePublished": "3/27/2015",
Try again? A spike below 100V or above 140V, could blow a capacitor. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). thanks. If they wont or cant fix it, call a electric motor repair shop to visit, or pull the pump and take it to them for service, or attempt the (easy) repair yourself. Something about level of placement of pump in relation to the water surface. Hard for me to say if the motor is shot, but it has sure had a rough life! Step 2: Verify that you have enough straight pipe before where you have installed your flow switch. It got very wet and tripped the breaker. We are a registered 501(c)3 non-profit that is funded by user donations. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. Hi Joe, could be a relay clicking, if you have a controller attached to the system, look for burnt or melted hi-speed relay. Then hold the shaft stationary to remove the impeller, and finally remove the housing. Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. The filter is clean. No matter where we move dial we have water coming out the back wash pipe. While the filter pump runs, you can here a drop for a millisecond every roughly 5 mins. If you have power there, and the motor is making no sound then I would inspect closely for a loose wire on the terminal board, or a loose switch in the back, or loose capacitor wire. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). Turn it off fully, then back on again. They disparate as they move through the pool. Could be a change in vibration, press down on the pump, to see if the tone changes. We dont have mechanical time clocksit is all digital. Any ideas on what may be going on? Pump motors are continuous duty, meaning that they are meant for continuous operation, it wont harm the motor, or cause it to overheat. Thanks Davy. Reprime the pump again, open water valves and test. Just be sure to buy the correct seal for your make/model pump, for the Powerflo Matrix pump, thats here: https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c SPX1250XZ2C. The pump/motor, is a power flow LX, 1.5 HP, model SP151521BC, & the Sand Filter is the pro series model S210T. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Inspect and tighten the suction and discharge connections using Teflon tape. If not, you should cut out the fitting and replace, smearing on some Blue RTV sealant, and then wrapping the threads completely in 3-4 layers of Teflon tape before screwing it into the pump. Also, because of this leak, would It cause my pressure to decrease? Will be using it as a stand alone. Same thing if I try to backwash. Hi Matt, my first guess would be an air leak on the suction side, most typically a loose pump lid (or no o-ring lube), or loose pipe that comes into the front of the pump (or no thread sealant on the threaded fitting), or sometimes a leaky suction side valve, or low water level, stuck skimmer weir Second guess would be a broken impeller, detached from the motor shaft. Signs of wear under the wear ring is normal, and it should be pumping normally. Step 3: Double check the wires on the flow switch for damage. The pump said it came prewired for 230V, but we are running 115V. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. Nothing seems to give it juice. I would inspect it for corrosion, wire tightness, water damage or insect damage. K-1766 Taylor Salt Test Make sure pump motor is set to accept 110V (may be wired to accept 220V), and that all wires for the cord are tight, and connected correctly to terminals L1 and L2, I have a hayward super pump model c48k2n143b1 sp2607x10a and i am trying to wire on the 115v but i dont have a switch to change from 220 or 115 and no diagram on the pump i try yesterday to pump work but was not pulling the water like it is suppose to and after 3 min the pump what very hot .. so i think it is on 220v are you able to help me. The repair for such an issue is to remove the 6 screws around the lid (dont lose the nuts), and pull the handle to lift the key assembly out of the valve body, where you can inspect the gasket, in the area of the backwash port. If that is what is happening to you Im sorry, but your motor is probably gasping its last breaths. Power on LED is intermittently on or off. Hayward North Star replaces capacitors Twice in a span of 3 month now pool pump not making any noise wondering if I can replace capacitor a third time. Hi I have a Hayward aquatrol above ground pool chlorine generator system. The waterfall pump should be a simple system, just a suction line and a return line (no valves? Thank you for the quick response. Usually its 4 bolts or its a clamp band that connects the seal plate to the volute or strainer housing. We recently had a makeover of our backyard where we replaced the concrete with pavers and it could very well be the sands and dust (yes, I had to vacuum the pool a couple times to get it clean) that got into the parts that helped speed up the demise of the pump. My EC40 bump handle doesnt feel right. Since the flow seems correct, could it be blockage elsewhere? Towards the end of last year the pump itself would work but the salt water fixture would not (like it would light up initially but then go to black), I wasnt sure if it was a short or something in either part but ignored it since the season was almost over. You should be able to lift up on the pump just slightly, to push something thin, 1/4 thick or less, beneath it. Hi Bobby, so you have power at the motor, but no noise. Display seems to be reading correctly and shows the cell is not generating. It is only in its 3rd season. It looks like no one has them in Stock and if I cant filter the pool, then it wont be usable. Hi David, these can sometimes be tricky to seal up, you are not alone. Motor again started humming and had to repeat the above steps each time I moved to backwash. Hi There I have a Hayward Super Pump VS pump. Question my Aquaririte is 3 years old. Other timers will have a different switch, but all should have someway to override. It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. Call Hayward and speak to their tech support people, for more precise advice. Hayward should be able to help, http://www.haywardnet.com see for contact info. Motors have a thermal overload switch to shut off the motor when it gets too hot. What can we check. Now wont turn on when I plug back in and my circuit breakers are not popped. Sanitization, Learn About Could also be a clog in the pipe. It is still running the same way, surging. Any ideas? Hi, my Hayward pump is about 5 years old. Use a flashlight, and you should see gears moving thru the small view hole. hayward super pump C48L2N134B1. Home / Pool Equipment / Pool Heaters & Heat Pumps / Hayward Pool Heater Troubleshooting Hayward Pool Heater Troubleshooting September 24, 2019 March 3, 2023 Mark Garcia For Drive Error Pump is Stalled error message, the first thing to check (as you did already) is that the motor shaft spins freely, and the impeller is not clogged. The waste tube on my filter is filler while my pump is running. Hi there, I have a 2-speed (hi and low) Hayward pump. I have cleaned the rubber gasket, made sure the springs touch to no avail. Make sure you. Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. Got another one, it too is doing the same thing. If you program the incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. To view these documents, you will need to download the free Acrobat Reader, which In particular, if the salt content of your pool water is too high, your metal screws, handrails, ladders, and covers will rust excessively. 24V after the transformer is present. Hayward Tristar VS manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true has some good troubleshooting tips. Only get big time cavitation and the basket empties about half. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. Check the shaft, to see that it is spinning freely, then check the wiring to be sure no bare wires are touching bare metal, or each other, or is corroded, and that all wiring is tight and clean. I cannot locate the model # on either but believe the filter is a c250. Motors are hot normally, 140 degrees or so, but if it shuts off and then resets and turns on again after 15-20 mins, it could be overheating, from voltage problems, loose connections, motor board, switch or capacitor wiring problems, or internal winding shorts. Either the pump lid oring is missing, or the lid (cover) is not tight, or a loose threaded pipe coming into the pump, or leaky valves (skimmer, main drain) air leaks are always in front of the pump. Secondly, it could be an air leak after the pump, around the filter, causing air to leak in when the pump shuts off (would be a water leak when the pump is on), which causes the water to drain out of the pump and back to the pool. Then check power (volts) coming into motor to verify and if it still wont come on (and makes no attempt to) its likely dead. Incorrect size breaker powering the outlet (below 15 amps). If very clogged, you can usually tell, because debris will float out and you can grab some of it with your fingertips or with pliers. Check the incoming motor voltage to be sure it is correct, too low or too high can cause problems. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. {
},
Thanks. Hi Carrie, sounds like an air leak, which is air being sucked into the pump, from somewhere in Front of the impeller, If your pump has an open bracket (where you can see the motor shaft), you can grab the shaft with your fingers or straight pliers, to break any rust. Now there is no water running from the pool to the motor basket. Check fan and shroud for blockage. I checked the possible issues that you mentioned hereno drain plugs on the systemdraining pool is done through the filter via a valve that is after the filter (Perflex). Last year the cap that you would remove to clean the filter was becoming more and more difficult to remove and get back on and now I cannot get it back on at all. I may have purchased a defective pump?? Inspect the following areas: If you see air bubbles coming from the return fittings on the pump, there may be an air leak on the suction side. Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Any idea what could be the culprit? 1. Shut down the power to the pump from the breaker for 15 minutes turn back on and try to run the pump. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . Im very new to pools & pool maintenance in general. Basically it ran normal and then would get loud, and then go back to normal. easier. I am very sure the water comes from underneath, not from plumbing fitting threads. I even removed the outflow from the filter and ran that directly in case the filter was clogged. look for a hi-voltage/low-voltage diagram on the motor label. Please help. I have purchased a Hayward SP 158015 Power-floLX series 1 1/2 horsepower Above Ground pool pump along with a Hayward S166T Proseries sandfilter 16 inch top mount for a 15 ft above ground proseries pool. If thats not the issue, is the pump sized correctly for the filter, and not under/over sized? Ive waited a few hours and tried again but no luck. You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. The leak at the bottom of the pump, determine if its coming from the top of the pump and dripping down the sides, or if the leak is coming from directly under the pump, in the first case its usually the exit pipe threads are loose, and in the second case, its a leaking shaft seal or leaking drain plug, or sometimes a leaking volute o-ring, or the large o-ring between the seal plate and the pump housing. Anyway, have you checked the cleaner line strainer? Below is a list of common issues that can arise with your Hayward pool heater. What could I be missing that would cause this? Hi Davy, Any ideas on how to fix this issue?? Any idea of the problem?? We just opened our pool up cleaned everything out put new D.E. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. That motor is sometimes used on the Hayward Superpump which is the only pump with a SQUARE pump basket. The pump has been running for 2 days. The blower will continue to run. Any idea? Capacitors are cheap to replace, order the exact MFD number, printed on it, or you can pick up local at a motor shop. Incorrect sizing can cause multiple problems, including low water flow. It had been running ok this summer. My pump is one horse power. All components of the Aqua Rite System are showing good readings and appears to be all set correctly. Well the electrician said it was a bad motor and to contact hayward to replace. I remplace it and now the sistem works!! Check for water under the display, or in the control box area. Could be clogged impeller? If not, keep reading. Third time turned off pump same thing happened with humming and eventually kicking in. Im wondering how to fix this problem and/or if a new pump is needed. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. Intermittently meaning it could run for days then trip, I could reset the breaker and have it trip again within a few hours, or it could run for days. The capacitor is at 9 oclock and the thermal regulator at 12 oclock. I bought a new pump thinking was something wrong with pump on off switch. If all is good, there is a possibility that the breaker or GFCI outlet is bad. We have tried switching outlets and that sometimes works. Do you have any idea what I need to do to remedy the problem. *new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. YOu can shim under a piece of rubber, or carpet, or cardboard which wont last long, but anything between the pump and the pad should quiet the pump, and take up space to prevent the vibration. Why would the pump and Polaris stop working at the same time? Hi Davy, When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. It leaks from the impeler case and is noisey, so assy B is no replacement. No lubricant is needed for spider gaskets. I went with the T3 because It was a significant cost saving and didnt think I would need one for larger pool. It can continue to run at that point but its almost like its running at 25% power or even less so we just turned it off. Cap is fine, so I lost. Hi Don, you have good troubleshooting skills, when flow is poor, it can either be a dirty filter or some obstruction after the pump which raises the filter tank pressure. Profile, Create a Pool Professional When I go to backwash the filter pump shuts down. Yesterday the breaker tripped. Look at the diagram on the top center of the motor, which may provide some help, if not, call Hayward (908) 355-7995 (U.S.). Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell - http://bit.ly/2TPpK5IStabilizer - http://bit.ly/3aCeEa7SUBSCRIBE for FREE swimming pool care and maintenance videos every week: http://bit.ly/SubscribeINYO ****VISIT our blog for weekly swimming pool tips, tricks, and more! "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. It's a little over 3 years old and the cell checked out fine. This is actually the second motor in 6 months. Shut it off & starting looking for help online. Im assuming that the motor makes no noise at all? Low speed should be enough flow to activate the flow switch. Replace with identical MFD number, printed on capacitor. Inspect the pipe/union connections on the suction side for loose connections or damaged pipes. Initially, look into the pump/strainer housing. Now it runs nice and quiet but still overheats and shuts off. We opened our pool today, and when we went out to turn off the Hayward pump, after it ran for 7 hours, the plug was so hot it burned my fingers when unplugging it. second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug.